MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 0.887 INCHES MAXIMUM" |
ABKW | OVERALL HEIGHT | 0.400 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 0.540 INCHES MAXIMUM" |
ADZC | ENVIRONMENTAL PROTECTION | MOISTURE PROOF" |
AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS" |
AFJQ | STORAGE TEMP RANGE | -62.0/+125.0 DEG CELSIUS" |
AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED" |
AGAV | END ITEM IDENTIFICATION | A05G0515-3, NEXT ASSEMBLIES A06G2509 (DASH NOS. 3401 AND 3402), USED ON A03G0100-1, WSD: STRATEGIC WEAPON SYSTEMS (POSEIDON AND TIRDENT); MISSILE, TOW (GROUND-TOW I AND II); TORPEDO, ADCAP 48; AIRCRAFTS, AWACS, E-3A; HAWKEYE E-2C; STARLIFTE" |
AGTA | BASIC SHAPE STYLE | RECTANGULAR OR SQUARE" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
ALBM | OPERATING CONTROL METHOD | AUTOMATIC" |
AMQY | INSTALLATION DESIGN | MODULE" |
AQZF | CONTROL TYPE | REMOTE" |
BHSX | III CIRCUIT CONSTRUCTION TYPE | SOLID STATE" |
BHTB | FREQUENCY PER CHANNEL | 24.0 MEGAHERTZ NOMINAL OPERATING CHANNEL" |
BJBP | CONNECTION TYPE AND LOCATION | ERR-060 GLAD HAND QUICK DISCONNECT" |
BJBW | CONNECTION CONTACT TYPE AND QUANTITY | 14 LITERS OF LIQUID NITROGEN DRAIN" |
BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 4.5 MINIMUM SINGLE VOLTAGE AND 5.5 MAXIMUM SINGLE VOLTAGE" |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT" |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL; ESD SENSITIVITY; 65 MAMPS INPUT CURRENT MAX AT 5.25 VOLT" |
TEST | TEST DATA DOCUMENT | 81349-MIL-PRF-55310 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLEC" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-55310/16 GOVERNMENT SPECIFICATION" |
ABHP | OVERALL LENGTH | 0.887 INCHES MAXIMUM" |
ABKW | OVERALL HEIGHT | 0.400 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 0.540 INCHES MAXIMUM" |
ADZC | ENVIRONMENTAL PROTECTION | MOISTURE PROOF" |
AFGA | OPERATING TEMP RANGE | -55.0/+125.0 DEG CELSIUS" |
AFJQ | STORAGE TEMP RANGE | -62.0/+125.0 DEG CELSIUS" |
AFSU | AVERAGE LIFE MEASUREMENT | NOT RATED" |
AGAV | END ITEM IDENTIFICATION | A05G0515-3, NEXT ASSEMBLIES A06G2509 (DASH NOS. 3401 AND 3402), USED ON A03G0100-1, WSD: STRATEGIC WEAPON SYSTEMS (POSEIDON AND TIRDENT); MISSILE, TOW (GROUND-TOW I AND II); TORPEDO, ADCAP 48; AIRCRAFTS, AWACS, E-3A; HAWKEYE E-2C; STARLIFTE" |
AGTA | BASIC SHAPE STYLE | RECTANGULAR OR SQUARE" |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED" |
ALBM | OPERATING CONTROL METHOD | AUTOMATIC" |
AMQY | INSTALLATION DESIGN | MODULE" |
AQZF | CONTROL TYPE | REMOTE" |
BHSX | III CIRCUIT CONSTRUCTION TYPE | SOLID STATE" |
BHTB | FREQUENCY PER CHANNEL | 24.0 MEGAHERTZ NOMINAL OPERATING CHANNEL" |
BJBP | CONNECTION TYPE AND LOCATION | ERR-060 GLAD HAND QUICK DISCONNECT" |
BJBW | CONNECTION CONTACT TYPE AND QUANTITY | 14 LITERS OF LIQUID NITROGEN DRAIN" |
BKFB | EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 4.5 MINIMUM SINGLE VOLTAGE AND 5.5 MAXIMUM SINGLE VOLTAGE" |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT" |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL; ESD SENSITIVITY; 65 MAMPS INPUT CURRENT MAX AT 5.25 VOLT" |
TEST | TEST DATA DOCUMENT | 81349-MIL-PRF-55310 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLEC" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-55310/16 GOVERNMENT SPECIFICATION" |