MRC | Criteria | Characteristic |
---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE" |
ADAQ | BODY LENGTH | 4.125 INCHES NOMINAL" |
ADAT | BODY WIDTH | 3.344 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 3.375 INCHES NOMINAL" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 2.625 INCHES NOMINAL" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.125 INCHES NOMINAL" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.216 INCHES NOMINAL" |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.625 INCHES NOMINAL" |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.938 INCHES NOMINAL" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AJEC | BOSS HEIGHT | 0.125 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 3" |
APNQ | ARC QUENCHING METHOD | AIR" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 500.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS AND 2500.0 DC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO" |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 200.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCK RESISTANT AND VIBRATION RESISTANT" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS" |
FEAT | SPECIAL FEATURES | CIRCUIT BREAKER SUPPLIED WITH TWO 12-24 MOUNTING SCREWS 4.125 IN. LG" |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 QUICK DISCONNECT, FEMALE" |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE" |
ADAQ | BODY LENGTH | 4.125 INCHES NOMINAL" |
ADAT | BODY WIDTH | 3.344 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 3.375 INCHES NOMINAL" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 2.625 INCHES NOMINAL" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.125 INCHES NOMINAL" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.216 INCHES NOMINAL" |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 0.625 INCHES NOMINAL" |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 2.938 INCHES NOMINAL" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AJEC | BOSS HEIGHT | 0.125 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 3" |
APNQ | ARC QUENCHING METHOD | AIR" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 30.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 500.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS AND 2500.0 DC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO" |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 10.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 200.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCK RESISTANT AND VIBRATION RESISTANT" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS" |
FEAT | SPECIAL FEATURES | CIRCUIT BREAKER SUPPLIED WITH TWO 12-24 MOUNTING SCREWS 4.125 IN. LG" |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS" |
TTQY | TERMINAL TYPE AND QUANTITY | 6 QUICK DISCONNECT, FEMALE" |