MRC | Criteria | Characteristic |
---|
AAJD | THREAD CLASS | 3B SINGLE PRESSURE CONNECTION" |
ABHP | OVERALL LENGTH | 2.830 INCHES NOMINAL" |
ABKV | OUTSIDE DIAMETER | 0.438 INCHES NOMINAL SINGLE CONNECTION" |
ADAQ | BODY LENGTH | 1.500 INCHES NOMINAL" |
ADAV | OVERALL DIAMETER | 1.625 INCHES NOMINAL" |
AJZC | PRESSURE SWITCH TYPE | ABSOLUTE" |
AXGY | MOUNTING METHOD | INPUT PORT" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQJB | PROOF PRESSURE | 60.00 POUNDS PER SQUARE INCH ABSOLUTE" |
CQJX | NOMINAL THREAD SIZE | 0.438 INCHES SINGLE PRESSURE CONNECTION" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CSCC | SENSING ELEMENT BURST PRESSURE | 80.00 POUNDS PER SQUARE INCH ABSOLUTE" |
CSCF | TERMINAL TYPE | CONNECTOR, RECEPTACLE" |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AND 3.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE" |
CTYX | CONTACT STIMULUS RATING | 35.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH ABSOLUTE AND 31.00 DEACTUATION POINT MINIMUM POUNDS PER SQUARE INCH ABSOLUTE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE" |
CTZL | PRESSURE CONNECTOR TYPE | FLARED, THREADED EXTERNAL SINGLE CONNECTION" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS" |
STYL | III STYLE DESIGNATOR | CYLINDRICAL" |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE PRESSURE CONNECTION" |
AAJD | THREAD CLASS | 3B SINGLE PRESSURE CONNECTION" |
ABHP | OVERALL LENGTH | 2.830 INCHES NOMINAL" |
ABKV | OUTSIDE DIAMETER | 0.438 INCHES NOMINAL SINGLE CONNECTION" |
ADAQ | BODY LENGTH | 1.500 INCHES NOMINAL" |
ADAV | OVERALL DIAMETER | 1.625 INCHES NOMINAL" |
AJZC | PRESSURE SWITCH TYPE | ABSOLUTE" |
AXGY | MOUNTING METHOD | INPUT PORT" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQJB | PROOF PRESSURE | 60.00 POUNDS PER SQUARE INCH ABSOLUTE" |
CQJX | NOMINAL THREAD SIZE | 0.438 INCHES SINGLE PRESSURE CONNECTION" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CSCC | SENSING ELEMENT BURST PRESSURE | 80.00 POUNDS PER SQUARE INCH ABSOLUTE" |
CSCF | TERMINAL TYPE | CONNECTOR, RECEPTACLE" |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD AND 3.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE" |
CTYX | CONTACT STIMULUS RATING | 35.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH ABSOLUTE AND 31.00 DEACTUATION POINT MINIMUM POUNDS PER SQUARE INCH ABSOLUTE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE" |
CTZL | PRESSURE CONNECTOR TYPE | FLARED, THREADED EXTERNAL SINGLE CONNECTION" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS" |
STYL | III STYLE DESIGNATOR | CYLINDRICAL" |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE PRESSURE CONNECTION" |