MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 2.430 INCHES MINIMUM AND 2.470 INCHES MAXIMUM" |
ABKW | OVERALL HEIGHT | 1.400 INCHES MINIMUM AND 1.500 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 0.900 INCHES MINIMUM AND 1.150 INCHES MAXIMUM" |
ABTB | MOUNTING HOLE DIAMETER | 0.334 INCHES MINIMUM AND 0.354 INCHES MAXIMUM" |
ABTJ | MOUNTING HOLE QUANTITY | 1" |
AFEC | DISTANCE FROM CENTER OF MOUNTING HOLE TO EDGE ALONG THE WIDTH | 0.480 INCHES MINIMUM AND 0.520 INCHES MAXIMUM" |
AXPE | CENTER TO CENTER DISTANCE BETWEEN FIRST AND THIRD MOUNTING HOLES | 1.500 INCHES NOMINAL" |
AZGM | MOUNTING FACILITY | UNTHREADED HOLE" |
BYGG | BLOCK HEIGHT | 0.670 INCHES MINIMUM AND 0.770 INCHES MAXIMUM" |
CWTD | CLAMPING HOLE QUANTITY | 2" |
CWWM | CLAMPING HOLE DIAMETER | 0.834 INCHES MINIMUM ALL HOLES AND 0.854 INCHES MAXIMUM ALL HOLES" |
CWXC | DISTANCE FROM END TO FIRST MOUNTING HOLE CENTER | 1.280 INCHES MINIMUM AND 1.380 INCHES MAXIMUM" |
MATT | MATERIAL | ALUMINUM" |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | QQ-A-250/2 FED SPEC SINGLE MATERIAL RESPONSE" |
SFTT | SURFACE TREATMENT | ANODIZE" |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-A-8625,TYPE 2,CLASS 1 MIL SPEC SINGLE TREATMENT RESPONSE" |
ABHP | OVERALL LENGTH | 2.430 INCHES MINIMUM AND 2.470 INCHES MAXIMUM" |
ABKW | OVERALL HEIGHT | 1.400 INCHES MINIMUM AND 1.500 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 0.900 INCHES MINIMUM AND 1.150 INCHES MAXIMUM" |
ABTB | MOUNTING HOLE DIAMETER | 0.334 INCHES MINIMUM AND 0.354 INCHES MAXIMUM" |
ABTJ | MOUNTING HOLE QUANTITY | 1" |
AFEC | DISTANCE FROM CENTER OF MOUNTING HOLE TO EDGE ALONG THE WIDTH | 0.480 INCHES MINIMUM AND 0.520 INCHES MAXIMUM" |
AXPE | CENTER TO CENTER DISTANCE BETWEEN FIRST AND THIRD MOUNTING HOLES | 1.500 INCHES NOMINAL" |
AZGM | MOUNTING FACILITY | UNTHREADED HOLE" |
BYGG | BLOCK HEIGHT | 0.670 INCHES MINIMUM AND 0.770 INCHES MAXIMUM" |
CWTD | CLAMPING HOLE QUANTITY | 2" |
CWWM | CLAMPING HOLE DIAMETER | 0.834 INCHES MINIMUM ALL HOLES AND 0.854 INCHES MAXIMUM ALL HOLES" |
CWXC | DISTANCE FROM END TO FIRST MOUNTING HOLE CENTER | 1.280 INCHES MINIMUM AND 1.380 INCHES MAXIMUM" |
MATT | MATERIAL | ALUMINUM" |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | QQ-A-250/2 FED SPEC SINGLE MATERIAL RESPONSE" |
SFTT | SURFACE TREATMENT | ANODIZE" |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | MIL-A-8625,TYPE 2,CLASS 1 MIL SPEC SINGLE TREATMENT RESPONSE" |