Search By:
Thanks for Visiting Us At ASAP AOG!

Thanks for Visiting Us At ASAP AOG! Before You Go, Why Not Take a Look at Our Aircraft Parts Catalog? You Can Get One of the Most Competitive Quotes On the Market In 15 Minutes Or Less.

Request for Quote

We use cookies to ensure that we give you an amazing experience on our website. If you continue to use this site we will assume that you are happy with it.

3076 Part of Transformer Technicians Inc with NSN 5950005238324 - Buy Now

Part No. : 3076
CAGE Code : 96253
Item Name : transformer power
NA

Part Number 3076 having (CAGE Code 96253) and FSC 5950 Coils and Transformers in stock with ready to ship. Get an instant quote for 3076 Transformer Power by Transformer Technicians Inc. Fill the form below with your desired order quantity, targeted price and the expected order-fulfilment date. Our dedicated account manager will get back to you within 15 minutes.


Please Fill Out Below Form
Required fields compulsory *

This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/terms-conditions.aspx. All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without CAGE code 6RE77 is void.

Note : We will not share your information to any third parties.


ASAP AOG is a eminent 3076 aircraft parts supplier to OEM, repair depot and other aviation sector. We are open for 7 days a week, 24 hours a day with instant Aircraft on Ground Support. All bill of materials can be sent via email to sales@asapaog.com in an excel format. Please feel free to call us at +1-714-705-4780.

NSN Information for Part Number 3076 with NSN 5950-00-523-8324, 5950005238324

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5950-00-523-8324

Item Description:

TRANSFORMER,POWER

5950005238324P
CIICHCCESDPMICCriticalityENAC
Part NumberISCRNVCRNCCHCCMSDSSADC
3076623

Characteristics Data of NSN 5950-00-523-8324, 5950005238324

MRCCriteriaCharacteristic
AARGRELIABILITY INDICATORNOT ESTABLISHEDNOT ESTABLISHED"
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP"
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP"
ABKWOVERALL HEIGHT6.263 INCHES NOMINAL6.263 INCHES NOMINAL"
ACZBFREQUENCY RATING50.0 HERTZ NOMINAL SINGLE COMPONENT OR 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT"
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT"
ACZXWINDING SHIELDING METHODINTERNALLY SHIELDED SINGLE COMPONENTINTERNALLY SHIELDED SINGLE COMPONENT"
ADAQBODY LENGTH4.563 INCHES NOMINAL4.563 INCHES NOMINAL"
ADATBODY WIDTH4.125 INCHES NOMINAL4.125 INCHES NOMINAL"
ADAUBODY HEIGHT5.313 INCHES NOMINAL5.313 INCHES NOMINAL"
AKNAINCLOSURE TYPEFULLY INCLOSEDFULLY INCLOSED"
AKPVMOUNTING FACILITY QUANTITY4 SINGLE GROUP4 SINGLE GROUP"
AXGYMOUNTING METHODTHREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP"
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT"
CMLPTHREAD QUANTITY PER INCH32 SINGLE GROUP32 SINGLE GROUP"
CQJXNOMINAL THREAD SIZE0.190 INCHES SINGLE GROUP0.190 INCHES SINGLE GROUP"
CRBZWINDING OPERATING CURRENT225.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY"
CRBZWINDING OPERATING CURRENT500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY"
CWJSWINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY"
CWJSWINDING OPERATING VOLTAGE2.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 4.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 6.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 8.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 90.00 AC VOL"
CWJSWINDING OPERATING VOLTAGE2.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 6.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 4.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 95.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 105.00 AC"
THSDTHREAD SERIES DESIGNATORUNF SINGLE GROUP"
TTQYTERMINAL TYPE AND QUANTITY20 TURRET"
AARGRELIABILITY INDICATORNOT ESTABLISHEDNOT ESTABLISHED"
ABKQCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH3.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP"
ABKRCENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP"
ABKWOVERALL HEIGHT6.263 INCHES NOMINAL6.263 INCHES NOMINAL"
ACZBFREQUENCY RATING50.0 HERTZ NOMINAL SINGLE COMPONENT OR 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT60.0 HERTZ NOMINAL SINGLE COMPONENT"
ACZCINPUT-OUTPUT PHASE RELATIONSHIPSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT"
ACZXWINDING SHIELDING METHODINTERNALLY SHIELDED SINGLE COMPONENTINTERNALLY SHIELDED SINGLE COMPONENT"
ADAQBODY LENGTH4.563 INCHES NOMINAL4.563 INCHES NOMINAL"
ADATBODY WIDTH4.125 INCHES NOMINAL4.125 INCHES NOMINAL"
ADAUBODY HEIGHT5.313 INCHES NOMINAL5.313 INCHES NOMINAL"
AKNAINCLOSURE TYPEFULLY INCLOSEDFULLY INCLOSED"
AKPVMOUNTING FACILITY QUANTITY4 SINGLE GROUP4 SINGLE GROUP"
AXGYMOUNTING METHODTHREADED STUD SINGLE GROUPTHREADED STUD SINGLE GROUP"
BPLCWINDING FUNCTION AND QUANTITY1 PRIMARY SINGLE COMPONENT AND 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT2 SECONDARY SINGLE COMPONENT"
CMLPTHREAD QUANTITY PER INCH32 SINGLE GROUP32 SINGLE GROUP"
CQJXNOMINAL THREAD SIZE0.190 INCHES SINGLE GROUP0.190 INCHES SINGLE GROUP"
CRBZWINDING OPERATING CURRENT225.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY"
CRBZWINDING OPERATING CURRENT500.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY"
CWJSWINDING OPERATING VOLTAGE115.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY"
CWJSWINDING OPERATING VOLTAGE2.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 4.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 6.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 8.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 90.00 AC VOL"
CWJSWINDING OPERATING VOLTAGE2.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 6.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 4.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY AND 95.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 105.00 AC"
THSDTHREAD SERIES DESIGNATORUNF SINGLE GROUP"
TTQYTERMINAL TYPE AND QUANTITY20 TURRET"

  Similar NSN Part Numbers to 3076

 ASAP AOG Offers
  • MRO Support
  • Wide Range of Parts
  • Quality Products
  • Competitive Prices
  • Instant Shipping
  • Best Customer Service
USA Flag

We are proud to supply every branch of the United States military

If You Have Multiple Parts Requirement, Then Upload Your Part List Here !

Upload
ASAP AOG Privacy Statement
Top Aircraft Products