MRC | Criteria | Characteristic |
---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE" |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL" |
ADAT | BODY WIDTH | 1.484 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.734 INCHES NOMINAL" |
AJEC | BOSS HEIGHT | 0.156 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 2" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 TERMINAL" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 17.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 30.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS" |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS" |
TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT, MALE AND 2 SCREW" |
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE" |
ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL" |
ADAT | BODY WIDTH | 1.484 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.734 INCHES NOMINAL" |
AJEC | BOSS HEIGHT | 0.156 INCHES NOMINAL" |
AKPX | POLE QUANTITY | 2" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 TERMINAL" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS AND TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 17.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 30.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT" |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS" |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS" |
TTQY | TERMINAL TYPE AND QUANTITY | 2 QUICK DISCONNECT, MALE AND 2 SCREW" |