MRC | Criteria | Characteristic |
---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERPROOF" |
ABHP | OVERALL LENGTH | 3.320 INCHES NOMINAL" |
ABKV | OUTSIDE DIAMETER | 0.250 INCHES NOMINAL SINGLE CONNECTION" |
ADAQ | BODY LENGTH | 1.370 INCHES MAXIMUM" |
ADAV | OVERALL DIAMETER | 1.090 INCHES MAXIMUM" |
AJZC | PRESSURE SWITCH TYPE | GAGE" |
AXGY | MOUNTING METHOD | CLAMP" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQJB | PROOF PRESSURE | 300.00 POUNDS PER SQUARE INCH" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION" |
CRTL | CRITICALITY CODE JUSTIFICATION | ADAQ AND ADAV AND ABHP AND CSCF" |
CSCC | SENSING ELEMENT BURST PRESSURE | 1000.00 POUNDS PER SQUARE INCH" |
CSCF | TERMINAL TYPE | QUICK DISCONNECT, MALE" |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES MOTOR LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES MOTOR LOAD SECOND VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE" |
CTYX | CONTACT STIMULUS RATING | 32.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 7.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZL | PRESSURE CONNECTOR TYPE | SHOULDER, UNTHREADED EXTERNAL SINGLE CONNECTION" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID" |
STYL | III STYLE DESIGNATOR | CYLINDRICAL" |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERPROOF" |
ABHP | OVERALL LENGTH | 3.320 INCHES NOMINAL" |
ABKV | OUTSIDE DIAMETER | 0.250 INCHES NOMINAL SINGLE CONNECTION" |
ADAQ | BODY LENGTH | 1.370 INCHES MAXIMUM" |
ADAV | OVERALL DIAMETER | 1.090 INCHES MAXIMUM" |
AJZC | PRESSURE SWITCH TYPE | GAGE" |
AXGY | MOUNTING METHOD | CLAMP" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQJB | PROOF PRESSURE | 300.00 POUNDS PER SQUARE INCH" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION" |
CRTL | CRITICALITY CODE JUSTIFICATION | ADAQ AND ADAV AND ABHP AND CSCF" |
CSCC | SENSING ELEMENT BURST PRESSURE | 1000.00 POUNDS PER SQUARE INCH" |
CSCF | TERMINAL TYPE | QUICK DISCONNECT, MALE" |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES MOTOR LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES MOTOR LOAD SECOND VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE" |
CTYX | CONTACT STIMULUS RATING | 32.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 7.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZL | PRESSURE CONNECTOR TYPE | SHOULDER, UNTHREADED EXTERNAL SINGLE CONNECTION" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID" |
STYL | III STYLE DESIGNATOR | CYLINDRICAL" |