MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 6.375 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.125 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKW | OVERALL HEIGHT | 3.687 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 5.907 INCHES MAXIMUM" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.220 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL" |
AKDX | WINDING QUANTITY | 2" |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL" |
APCN | COIL QUANTITY | 2" |
APNP | DUTY TYPE | INTERMITTENT" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE SINGLE MOUNTING FACILITY" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS" |
CBME | III CUBIC MEASURE | 138.842 CUBIC INCHES" |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION" |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 0.2 MILLIAMPERES AC ALL WINDINGS" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC RESISTIVE LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 75.0 AMPERES AC INDUCTIVE LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 75.0 AMPERES AC MOTOR LOAD" |
SPCL | SPECIAL TEST FEATURES | OPERATING TEMP RANGE M55 DEG C TO P85 DEG C" |
TTQY | TERMINAL TYPE AND QUANTITY | 13 THREADED STUD ALL FUNCTIONS" |
ABHP | OVERALL LENGTH | 6.375 INCHES MAXIMUM" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.125 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
ABKW | OVERALL HEIGHT | 3.687 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 5.907 INCHES MAXIMUM" |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.220 INCHES NOMINAL SINGLE MOUNTING FACILITY" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL" |
AKDX | WINDING QUANTITY | 2" |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL" |
APCN | COIL QUANTITY | 2" |
APNP | DUTY TYPE | INTERMITTENT" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE SINGLE MOUNTING FACILITY" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS" |
CBME | III CUBIC MEASURE | 138.842 CUBIC INCHES" |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION" |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 0.2 MILLIAMPERES AC ALL WINDINGS" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 100.0 AMPERES AC RESISTIVE LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 75.0 AMPERES AC INDUCTIVE LOAD" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 75.0 AMPERES AC MOTOR LOAD" |
SPCL | SPECIAL TEST FEATURES | OPERATING TEMP RANGE M55 DEG C TO P85 DEG C" |
TTQY | TERMINAL TYPE AND QUANTITY | 13 THREADED STUD ALL FUNCTIONS" |