MRC | Criteria | Characteristic |
---|
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM" |
ADAQ | BODY LENGTH | 0.643 INCHES NOMINAL" |
ADAT | BODY WIDTH | 0.593 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 0.115 INCHES NOMINAL" |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.390 INCHES MINIMUM AND 0.410 INCHES MAXIMUM" |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S)" |
CQBF | INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 500.0 MEGOHMS" |
CQBQ | CAPACITANCE VALUE PER SECTION | 0.500 MICROFARADS SINGLE SECTION" |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM" |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 50.0 DC SINGLE SECTION" |
CRTL | CRITICALITY CODE JUSTIFICATION | TEST" |
CRTP | TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION" |
CWJK | CASE MATERIAL | CERAMIC" |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 1000.0 MEGOHMS" |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 2.5000" |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER" |
TEST | TEST DATA DOCUMENT | 94756-A441-0761 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR" |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD" |
AAQL | BODY STYLE | W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM" |
ADAQ | BODY LENGTH | 0.643 INCHES NOMINAL" |
ADAT | BODY WIDTH | 0.593 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 0.115 INCHES NOMINAL" |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.390 INCHES MINIMUM AND 0.410 INCHES MAXIMUM" |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S)" |
CQBF | INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP | 500.0 MEGOHMS" |
CQBQ | CAPACITANCE VALUE PER SECTION | 0.500 MICROFARADS SINGLE SECTION" |
CQJJ | NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM" |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 50.0 DC SINGLE SECTION" |
CRTL | CRITICALITY CODE JUSTIFICATION | TEST" |
CRTP | TOLERANCE RANGE PER SECTION | -10.00/+10.00 PERCENT SINGLE SECTION" |
CWJK | CASE MATERIAL | CERAMIC" |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 1000.0 MEGOHMS" |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 2.5000" |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER" |
TEST | TEST DATA DOCUMENT | 94756-A441-0761 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR" |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD" |