MRC | Criteria | Characteristic |
---|
AAPN | SECTION QUANTITY | 1" |
AAQL | BODY STYLE | CYLINDRICAL SERVO MOUNTED" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
AAVL | PILOT DIAMETER | 0.9995 INCHES MINIMUM AND 1.0000 INCHES MAXIMUM" |
AAVM | PILOT LENGTH | 0.0620 INCHES NOMINAL" |
ABPA | UNDERCUT DIAMETER | 1.000 INCHES NOMINAL" |
ABPC | UNDERCUT WIDTH | 0.0620 INCHES NOMINAL" |
ABPM | BODY DIAMETER | 1.125 INCHES NOMINAL" |
ABWV | SHAFT DIAMETER | 0.2496 INCHES MINIMUM AND 0.2499 INCHES MAXIMUM" |
ABXF | SHAFT LENGTH | 0.875 INCHES NOMINAL" |
ADAQ | BODY LENGTH | 0.703 INCHES MAXIMUM" |
AECZ | MOUNTING LIP DIAMETER | 1.1250 INCHES NOMINAL" |
AEDA | MOUNTING LIP DEPTH | 0.0620 INCHES NOMINAL" |
AEDX | SHAFT STYLE | ROUND" |
AEFD | ACTUATOR TYPE | SINGLE SHAFT" |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 350.0 MINIMUM" |
APXH | TERMINAL LOCATION | RADIALLY POSITIONED OVER MORE THAN HALF THE CIRCUMFERENCE" |
AXGY | MOUNTING METHOD | CLAMP RING" |
CBBL | FEATURES PROVIDED | NONMETALLIC SHAFT" |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 15.0 KILOHMS SINGLE SECTION" |
CQCH | TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION | 179.0 SINGLE SECTION AND 225.0 SINGLE SECTION" |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL" |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION" |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION" |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 3.0 FREE AIR SINGLE SECTION" |
CRJS | FIXED TAP QUANTITY PER SECTION | 2 SINGLE SECTION" |
CRKS | TAP LOCATION TOLERANCE PER SECTION | -2.0 TO 2.0 DEG ANGULAR ROTATION SINGLE SECTION" |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION" |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CONTINUOUS MOTION" |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION" |
TEST | TEST DATA DOCUMENT | 80249-730197 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI" |
TTQY | TERMINAL TYPE AND QUANTITY | 5 TURRET" |
AAPN | SECTION QUANTITY | 1" |
AAQL | BODY STYLE | CYLINDRICAL SERVO MOUNTED" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
AAVL | PILOT DIAMETER | 0.9995 INCHES MINIMUM AND 1.0000 INCHES MAXIMUM" |
AAVM | PILOT LENGTH | 0.0620 INCHES NOMINAL" |
ABPA | UNDERCUT DIAMETER | 1.000 INCHES NOMINAL" |
ABPC | UNDERCUT WIDTH | 0.0620 INCHES NOMINAL" |
ABPM | BODY DIAMETER | 1.125 INCHES NOMINAL" |
ABWV | SHAFT DIAMETER | 0.2496 INCHES MINIMUM AND 0.2499 INCHES MAXIMUM" |
ABXF | SHAFT LENGTH | 0.875 INCHES NOMINAL" |
ADAQ | BODY LENGTH | 0.703 INCHES MAXIMUM" |
AECZ | MOUNTING LIP DIAMETER | 1.1250 INCHES NOMINAL" |
AEDA | MOUNTING LIP DEPTH | 0.0620 INCHES NOMINAL" |
AEDX | SHAFT STYLE | ROUND" |
AEFD | ACTUATOR TYPE | SINGLE SHAFT" |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 350.0 MINIMUM" |
APXH | TERMINAL LOCATION | RADIALLY POSITIONED OVER MORE THAN HALF THE CIRCUMFERENCE" |
AXGY | MOUNTING METHOD | CLAMP RING" |
CBBL | FEATURES PROVIDED | NONMETALLIC SHAFT" |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 15.0 KILOHMS SINGLE SECTION" |
CQCH | TAP LOCATION FROM CCW TERMINAL PER SECTION IN DEG OF EFFECTIVE ELECTRICAL ROTATION | 179.0 SINGLE SECTION AND 225.0 SINGLE SECTION" |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL" |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION" |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0 TO 100.0 SINGLE SECTION" |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 3.0 FREE AIR SINGLE SECTION" |
CRJS | FIXED TAP QUANTITY PER SECTION | 2 SINGLE SECTION" |
CRKS | TAP LOCATION TOLERANCE PER SECTION | -2.0 TO 2.0 DEG ANGULAR ROTATION SINGLE SECTION" |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION" |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CONTINUOUS MOTION" |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 70.0 SINGLE SECTION" |
TEST | TEST DATA DOCUMENT | 80249-730197 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI" |
TTQY | TERMINAL TYPE AND QUANTITY | 5 TURRET" |