MRC | Criteria | Characteristic |
---|
AAPN | SECTION QUANTITY | 1" |
AAQL | BODY STYLE | CYLINDRICAL" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHP | III OVERALL LENGTH | 0.710 INCHES NOMINAL" |
ABJT | TERMINAL LENGTH | 0.160 INCHES NOMINAL" |
ABPM | BODY DIAMETER | 0.500 INCHES NOMINAL" |
ADAQ | BODY LENGTH | 0.550 INCHES NOMINAL" |
ADAV | III OVERALL DIAMETER | 0.500 INCHES NOMINAL" |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE" |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 345.0 NOMINAL" |
AEFK | MAXIMUM STARTING TORQUE | 10.00 INCH-OUNCES" |
AEFL | MAXIMUM RUNNING TORQUE | 2.00 INCH-OUNCES" |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL" |
APXH | TERMINAL LOCATION | REAR END" |
AXGY | MOUNTING METHOD | TERMINAL" |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 50.0 KILOHMS SINGLE SECTION" |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL" |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL" |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION" |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 2.0 FREE AIR SINGLE SECTION" |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION" |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CONTINUOUS MOTION" |
CSCY | TEMP COEFFICIENT OF RESISTANCE WIRE PER SECTION IN PPM PER DEG CELSIUS | -20.0 TO 20.0 SINGLE SECTION" |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION" |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN" |
AAPN | SECTION QUANTITY | 1" |
AAQL | BODY STYLE | CYLINDRICAL" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABHP | III OVERALL LENGTH | 0.710 INCHES NOMINAL" |
ABJT | TERMINAL LENGTH | 0.160 INCHES NOMINAL" |
ABPM | BODY DIAMETER | 0.500 INCHES NOMINAL" |
ADAQ | BODY LENGTH | 0.550 INCHES NOMINAL" |
ADAV | III OVERALL DIAMETER | 0.500 INCHES NOMINAL" |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE" |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 345.0 NOMINAL" |
AEFK | MAXIMUM STARTING TORQUE | 10.00 INCH-OUNCES" |
AEFL | MAXIMUM RUNNING TORQUE | 2.00 INCH-OUNCES" |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL" |
APXH | TERMINAL LOCATION | REAR END" |
AXGY | MOUNTING METHOD | TERMINAL" |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 50.0 KILOHMS SINGLE SECTION" |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 360.0 NOMINAL" |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL" |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION" |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 2.0 FREE AIR SINGLE SECTION" |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -5.0 TO 5.0 SINGLE SECTION" |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | CONTINUOUS MOTION" |
CSCY | TEMP COEFFICIENT OF RESISTANCE WIRE PER SECTION IN PPM PER DEG CELSIUS | -20.0 TO 20.0 SINGLE SECTION" |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION" |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN" |