MRC | Criteria | Characteristic |
---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND" |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.230 INCHES NOMINAL" |
AMQN | III CONDUCTOR QUANTITY | 3" |
ASGF | TRACER COLOR | BLACK SINGLE TRACER FIRST CONDUCTOR" |
ASGF | TRACER COLOR | BROWN SINGLE TRACER SECOND CONDUCTOR" |
ASGF | TRACER COLOR | RED SINGLE TRACER THIRD CONDUCTOR" |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS" |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS" |
CXDC | ROUND CONDUCTOR SIZE | 20 AWG ALL CONDUCTORS" |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 32 ALL CONDUCTORS" |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 3 SINGLES" |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS" |
FEAT | SPECIAL FEATURES | OUTER NYLON BRAID IS INPREGNATED WITH LACQUER" |
HUES | COLOR | WHITE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS" |
MATT | MATERIAL | COPPER 3RD POSITION SHIELD BRAID, METALLIC CABLE" |
MATT | MATERIAL | COPPER 4TH POSITION SHIELD BRAID, METALLIC CABLE" |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS" |
MATT | MATERIAL | PLASTIC ETHYLENE-TETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS" |
MATT | MATERIAL | PLASTIC POLYAMIDE 5TH POSITION BRAID, NON-METALLIC CABLE" |
MATT | MATERIAL | PLASTIC POLYETHYLENE 2ND POSITION TAPE CABLE" |
SFTT | SURFACE TREATMENT | TIN 3RD POSITION SHIELD BRAID, METALLIC CABLE" |
SFTT | SURFACE TREATMENT | TIN 4TH POSITION SHIELD BRAID, METALLIC CABLE" |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS" |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND" |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.230 INCHES NOMINAL" |
AMQN | III CONDUCTOR QUANTITY | 3" |
ASGF | TRACER COLOR | BLACK SINGLE TRACER FIRST CONDUCTOR" |
ASGF | TRACER COLOR | BROWN SINGLE TRACER SECOND CONDUCTOR" |
ASGF | TRACER COLOR | RED SINGLE TRACER THIRD CONDUCTOR" |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS" |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS" |
CXDC | ROUND CONDUCTOR SIZE | 20 AWG ALL CONDUCTORS" |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 32 ALL CONDUCTORS" |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 3 SINGLES" |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS" |
FEAT | SPECIAL FEATURES | OUTER NYLON BRAID IS INPREGNATED WITH LACQUER" |
HUES | COLOR | WHITE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS" |
MATT | MATERIAL | COPPER 3RD POSITION SHIELD BRAID, METALLIC CABLE" |
MATT | MATERIAL | COPPER 4TH POSITION SHIELD BRAID, METALLIC CABLE" |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS" |
MATT | MATERIAL | PLASTIC ETHYLENE-TETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS" |
MATT | MATERIAL | PLASTIC POLYAMIDE 5TH POSITION BRAID, NON-METALLIC CABLE" |
MATT | MATERIAL | PLASTIC POLYETHYLENE 2ND POSITION TAPE CABLE" |
SFTT | SURFACE TREATMENT | TIN 3RD POSITION SHIELD BRAID, METALLIC CABLE" |
SFTT | SURFACE TREATMENT | TIN 4TH POSITION SHIELD BRAID, METALLIC CABLE" |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS" |