JA3S-A3-LS-04-D-A-3A-2 Part of Eaton Industrial Corporation with NSN 5925004847695 - Buy Now

Part No. : JA3S-A3-LS-04-D-A-3A-2
Alternate P/N: JA3SA3LS04DA3A2
CAGE Code : S4702
Item Name : circuit breaker
NA

Part Number JA3S-A3-LS-04-D-A-3A-2 having (CAGE Code S4702) and FSC 5925 Circuit Breakers in stock with ready to ship. Get an instant quote for JA3S-A3-LS-04-D-A-3A-2 Circuit Breaker by Eaton Industrial Corporation. Fill the form below with your desired order quantity, targeted price and the expected order-fulfilment date. Our dedicated account manager will get back to you within 15 minutes.


Please Fill Out Below Form
Required fields compulsory *

This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/terms-conditions.aspx. All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without CAGE code 6RE77 is void.

Note : We will not share your information to any third parties.


ASAP AOG is a eminent JA3S-A3-LS-04-D-A-3A-2 aircraft parts supplier to OEM, repair depot and other aviation sector. We are open for 7 days a week, 24 hours a day with instant Aircraft on Ground Support. All bill of materials can be sent via email to sales@asapaog.com in an excel format. Please feel free to call us at +1-714-705-4780.

NSN Information for Part Number JA3S-A3-LS-04-D-A-3A-2 with NSN 5925-00-484-7695, 5925004847695

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5925-00-484-7695

Item Description:

Circuit Breaker

59250048476950P
CIICHCCESDPMICCriticalityENAC
U U
Part NumberISCRNVCRNCCHCCMSDSSADC
Ja3s-A3-Ls-04-D-A-3a-2225

Characteristics Data of NSN 5925-00-484-7695, 5925004847695

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE"
ADAQBODY LENGTH1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM"
ADATBODY WIDTH2.245 INCHES MINIMUM AND 2.255 INCHES MAXIMUM"
ADTVCASE MATERIALPLASTIC"
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.555 INCHES MINIMUM AND 1.565 INCHES MAXIMUM"
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM"
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.655 INCHES MINIMUM AND 1.665 INCHES MAXIMUM"
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM"
AFJNFRAGILITY FACTORMODERATELY RUGGED"
AJECBOSS HEIGHT0.125 INCHES MINIMUM AND 0.135 INCHES MAXIMUM"
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE1.835 INCHES MINIMUM AND 1.845 INCHES MAXIMUM"
AKPXPOLE QUANTITY3"
APNQARC QUENCHING METHODMAGNETIC BLOWOUT"
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE"
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE"
CMLPTHREAD QUANTITY PER INCH32"
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE3.0 AMPERES AC ALL LOCATIONS"
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC ALL LOCATIONS"
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC ALL LOCATIONS"
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS"
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS"
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS"
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS"
CPRQRESET METHODMANUAL"
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE"
CPRTMANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE"
CPRWACTUATOR FUNCTIONTRIP-RESET"
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE"
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED"
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS"
CQJXNOMINAL THREAD SIZE0.138 INCHES"
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS"
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF"
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS"
THSDTHREAD SERIES DESIGNATORUNC"
TTQYTERMINAL TYPE AND QUANTITY6 TAB, SOLDER LUG"
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE"
ADAQBODY LENGTH1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM"
ADATBODY WIDTH2.245 INCHES MINIMUM AND 2.255 INCHES MAXIMUM"
ADTVCASE MATERIALPLASTIC"
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.555 INCHES MINIMUM AND 1.565 INCHES MAXIMUM"
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM"
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.655 INCHES MINIMUM AND 1.665 INCHES MAXIMUM"
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM"
AFJNFRAGILITY FACTORMODERATELY RUGGED"
AJECBOSS HEIGHT0.125 INCHES MINIMUM AND 0.135 INCHES MAXIMUM"
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE1.835 INCHES MINIMUM AND 1.845 INCHES MAXIMUM"
AKPXPOLE QUANTITY3"
APNQARC QUENCHING METHODMAGNETIC BLOWOUT"
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE"
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE"
CMLPTHREAD QUANTITY PER INCH32"
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE3.0 AMPERES AC ALL LOCATIONS"
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC ALL LOCATIONS"
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1000.0 AC ALL LOCATIONS"
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS"
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS"
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS"
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS"
CPRQRESET METHODMANUAL"
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE"
CPRTMANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE"
CPRWACTUATOR FUNCTIONTRIP-RESET"
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE"
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED"
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS"
CQJXNOMINAL THREAD SIZE0.138 INCHES"
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS"
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDDUSTPROOF AND FUNGUS PROOF"
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS"
THSDTHREAD SERIES DESIGNATORUNC"
TTQYTERMINAL TYPE AND QUANTITY6 TAB, SOLDER LUG"

  Similar NSN Part Numbers to JA3S-A3-LS-04-D-A-3A-2

 ASAP AOG Offers
  • MRO Support
  • Wide Range of Parts
  • Quality Products
  • Competitive Prices
  • Instant Shipping
  • Best Customer Service
USA Flag

We are proud to supply every branch of the United States military

If You Have Multiple Parts Requirement, Then Upload Your Part List Here !

Upload
ASAP AOG Privacy Statement
Top Aircraft Products