MRC | Criteria | Characteristic |
---|
AARA | TERMINAL QUANTITY | 9" |
AARB | TERMINAL TYPE | FLEXIBLE LEAD" |
ABDR | MOUNTING PROVISION | HOLES" |
ABHP | OVERALL LENGTH | 1.250 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 4.150 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 1.000 INCHES NOMINAL" |
ADTV | CASE MATERIAL | METAL" |
AFGA | OPERATING TEMP RANGE | +0.0/+60.0 DEG CELSIUS" |
AKPV | MOUNTING FACILITY QUANTITY | 4" |
ALGC | MOUNTING CONFIGURATION | FOUR 4-40 UNC-2B THD MTG HOLES ON 0.938 IN. BY 0.688 IN. MTG CENTERS" |
APAG | COIL TYPE | ISOLATED" |
APFR | CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW, OPEN NEUTRAL AND SINGLE POLE,DOUBLE THROW,CLOSED NEUTRAL" |
APNX | INPUT VOLTAGE RATING | 10.0 DC VOLTS NOMINAL" |
APQB | III UNIT TYPE | ANY ACCEPTABLE" |
AWYX | MOUNTING FACILITY SIZE | 0.112 IN. DIA" |
AXGY | MOUNTING METHOD | HOLE" |
AXNN | HERMETICALLY SEALED FEATURE | NOT PROVIDED" |
AZSL | INPUT CURRENT RATING | 66.0 MILLIAMPERES NOMINAL" |
BGRB | DRIVE VOLTAGE RELATIONSHIP TO INPUT VOLTAGE | UNEQUAL" |
BGRC | DRIVE VOLTAGE RATING | 8.0 MAXIMUM VOLTS ANY ACCEPTABLE" |
BGRH | OUTPUT/INPUT VOLTAGE RELATIONSHIP | NOT RATED" |
BGRK | CONTACT OPERATION SEQUENCE | MAKES BEFORE BREAKS AND BREAKS BEFORE MAKES" |
BGRL | CONTACT VOLTAGE RATING | 0.0 MAXIMUM VOLTS DRY AND 10.0 MAXIMUM VOLTS WITH RETAINING CHAIN AND 1.0 MAXIMUM VOLTS DRY AND 50.0 MAXIMUM VOLTS WITH RETAINING CHAIN" |
BGRS | PLUG IN MOUNTING FEATURE | NOT PROVIDED" |
BGRY | CONNECTION LOCATION | TOP" |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS GOLD AND CONTACTS PLATINUM AND CONTACTS RHODIUM" |
PRMT | PRECIOUS MATERIAL | GOLD AND PLATINUM AND RHODIUM" |
AARA | TERMINAL QUANTITY | 9" |
AARB | TERMINAL TYPE | FLEXIBLE LEAD" |
ABDR | MOUNTING PROVISION | HOLES" |
ABHP | OVERALL LENGTH | 1.250 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 4.150 INCHES MAXIMUM" |
ABMK | OVERALL WIDTH | 1.000 INCHES NOMINAL" |
ADTV | CASE MATERIAL | METAL" |
AFGA | OPERATING TEMP RANGE | +0.0/+60.0 DEG CELSIUS" |
AKPV | MOUNTING FACILITY QUANTITY | 4" |
ALGC | MOUNTING CONFIGURATION | FOUR 4-40 UNC-2B THD MTG HOLES ON 0.938 IN. BY 0.688 IN. MTG CENTERS" |
APAG | COIL TYPE | ISOLATED" |
APFR | CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW, OPEN NEUTRAL AND SINGLE POLE,DOUBLE THROW,CLOSED NEUTRAL" |
APNX | INPUT VOLTAGE RATING | 10.0 DC VOLTS NOMINAL" |
APQB | III UNIT TYPE | ANY ACCEPTABLE" |
AWYX | MOUNTING FACILITY SIZE | 0.112 IN. DIA" |
AXGY | MOUNTING METHOD | HOLE" |
AXNN | HERMETICALLY SEALED FEATURE | NOT PROVIDED" |
AZSL | INPUT CURRENT RATING | 66.0 MILLIAMPERES NOMINAL" |
BGRB | DRIVE VOLTAGE RELATIONSHIP TO INPUT VOLTAGE | UNEQUAL" |
BGRC | DRIVE VOLTAGE RATING | 8.0 MAXIMUM VOLTS ANY ACCEPTABLE" |
BGRH | OUTPUT/INPUT VOLTAGE RELATIONSHIP | NOT RATED" |
BGRK | CONTACT OPERATION SEQUENCE | MAKES BEFORE BREAKS AND BREAKS BEFORE MAKES" |
BGRL | CONTACT VOLTAGE RATING | 0.0 MAXIMUM VOLTS DRY AND 10.0 MAXIMUM VOLTS WITH RETAINING CHAIN AND 1.0 MAXIMUM VOLTS DRY AND 50.0 MAXIMUM VOLTS WITH RETAINING CHAIN" |
BGRS | PLUG IN MOUNTING FEATURE | NOT PROVIDED" |
BGRY | CONNECTION LOCATION | TOP" |
PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS GOLD AND CONTACTS PLATINUM AND CONTACTS RHODIUM" |
PRMT | PRECIOUS MATERIAL | GOLD AND PLATINUM AND RHODIUM" |