MRC | Criteria | Characteristic |
---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABJT | TERMINAL LENGTH | 0.250 INCHES NOMINAL" |
ADAQ | BODY LENGTH | 0.400 INCHES NOMINAL" |
ADAR | BODY OUTSIDE DIAMETER | 0.043 INCHES NOMINAL" |
AEBT | TERMINAL DIAMETER | 0.004 INCHES NOMINAL" |
AEHX | MAXIMUM POWER DISSIPATION RATING | 2.00 WATTS" |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 125.0 DEG CELSIUS" |
AEHZ | MAXIMUM OPERATING TEMP | 315.6 DEG CELSIUS" |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 2.0" |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 0.7" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -25.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 151.9 OHMS 4TH RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 328.7 OHMS 3RD RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 40.6 OHMS 6TH RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 74.7 OHMS 5TH RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 8.7 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT" |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0/+15.0 ALL RESISTANCE-TEMPERATURE POINTS" |
AKNA | INCLOSURE TYPE | ENCAPSULATED" |
CQWD | III ZERO POWER RESISTANCE | 830.000 OHMS" |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -20.0/+20.0" |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0" |
STYL | STYLE DESIGNATOR | SEALED OR COATED BEAD" |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABJT | TERMINAL LENGTH | 0.250 INCHES NOMINAL" |
ADAQ | BODY LENGTH | 0.400 INCHES NOMINAL" |
ADAR | BODY OUTSIDE DIAMETER | 0.043 INCHES NOMINAL" |
AEBT | TERMINAL DIAMETER | 0.004 INCHES NOMINAL" |
AEHX | MAXIMUM POWER DISSIPATION RATING | 2.00 WATTS" |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 125.0 DEG CELSIUS" |
AEHZ | MAXIMUM OPERATING TEMP | 315.6 DEG CELSIUS" |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 2.0" |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 0.7" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -25.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT" |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 151.9 OHMS 4TH RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 2.4 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 328.7 OHMS 3RD RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 40.6 OHMS 6TH RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 74.7 OHMS 5TH RESISTANCE-TEMPERATURE POINT" |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 8.7 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT" |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.0/+15.0 ALL RESISTANCE-TEMPERATURE POINTS" |
AKNA | INCLOSURE TYPE | ENCAPSULATED" |
CQWD | III ZERO POWER RESISTANCE | 830.000 OHMS" |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -20.0/+20.0" |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0" |
STYL | STYLE DESIGNATOR | SEALED OR COATED BEAD" |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD" |