MRC | Criteria | Characteristic |
---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABTD | MOUNTING SLOT WIDTH | 0.188 INCHES NOMINAL SINGLE GROUP" |
ACZB | FREQUENCY RATING | 45.0 HERTZ MINIMUM SINGLE COMPONENT AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT AND INTERNAL SHIELD GROUNDED TO TERMINAL SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.312 INCHES MAXIMUM" |
ADAT | BODY WIDTH | 2.062 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 3.125 INCHES MAXIMUM" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 230.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY AND 250.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 55.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
TTQY | TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.688 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP" |
ABTD | MOUNTING SLOT WIDTH | 0.188 INCHES NOMINAL SINGLE GROUP" |
ACZB | FREQUENCY RATING | 45.0 HERTZ MINIMUM SINGLE COMPONENT AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT" |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT" |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT AND INTERNAL SHIELD GROUNDED TO TERMINAL SINGLE COMPONENT" |
ADAQ | BODY LENGTH | 2.312 INCHES MAXIMUM" |
ADAT | BODY WIDTH | 2.062 INCHES MAXIMUM" |
ADAU | BODY HEIGHT | 3.125 INCHES MAXIMUM" |
AKNA | INCLOSURE TYPE | FULLY INCLOSED" |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP" |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP" |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT" |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY" |
CRBZ | WINDING OPERATING CURRENT | 100.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 230.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY AND 250.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY" |
CWJS | WINDING OPERATING VOLTAGE | 55.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY" |
CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY" |
TTQY | TERMINAL TYPE AND QUANTITY | 12 WIRE LEAD" |