MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 1.780 INCHES NOMINAL" |
ADAV | OVERALL DIAMETER | 0.370 INCHES MAXIMUM" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AKDX | WINDING QUANTITY | 2" |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL" |
APCN | COIL QUANTITY | 2" |
APNA | WINDING DC RESISTANCE RATING | 120.0 OHMS NOMINAL SINGLE WINDING" |
APNP | DUTY TYPE | CONTINUOUS" |
APNQ | ARC QUENCHING METHOD | AIR" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 7 TERMINAL SINGLE MOUNTING FACILITY" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT" |
CRXH | TIME DELAY | 0.0015 SECONDS MAXIMUM FIXED OPERATE TIME" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD200.0 MILLIAMPERES DC INDUCTIVE LOAD100.0 MILLIAMPERES DC LAMP LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC" |
FEAT | SPECIAL FEATURES | FAILURE RATE 1.0 PERCENT PER 10,000 CYCLES" |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI" |
TTQY | TERMINAL TYPE AND QUANTITY | 7 WIRE HOOK ALL FUNCTIONS" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/8 GOVERNMENT SPECIFICATION" |
ABHP | OVERALL LENGTH | 1.780 INCHES NOMINAL" |
ADAV | OVERALL DIAMETER | 0.370 INCHES MAXIMUM" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AKDX | WINDING QUANTITY | 2" |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL" |
APCN | COIL QUANTITY | 2" |
APNA | WINDING DC RESISTANCE RATING | 120.0 OHMS NOMINAL SINGLE WINDING" |
APNP | DUTY TYPE | CONTINUOUS" |
APNQ | ARC QUENCHING METHOD | AIR" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 7 TERMINAL SINGLE MOUNTING FACILITY" |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE" |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS" |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT" |
CRXH | TIME DELAY | 0.0015 SECONDS MAXIMUM FIXED OPERATE TIME" |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING" |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD200.0 MILLIAMPERES DC INDUCTIVE LOAD100.0 MILLIAMPERES DC LAMP LOAD" |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC" |
FEAT | SPECIAL FEATURES | FAILURE RATE 1.0 PERCENT PER 10,000 CYCLES" |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI" |
TTQY | TERMINAL TYPE AND QUANTITY | 7 WIRE HOOK ALL FUNCTIONS" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/8 GOVERNMENT SPECIFICATION" |