MRC | Criteria | Characteristic |
---|
ABHP | III OVERALL LENGTH | 0.322 INCHES MINIMUM AND 0.366 INCHES MAXIMUM" |
ABKW | OVERALL HEIGHT | 0.065 INCHES MINIMUM AND 0.095 INCHES MAXIMUM" |
ABPM | BODY DIAMETER | 0.248 INCHES MINIMUM AND 0.278 INCHES MAXIMUM" |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR" |
AXGY | MOUNTING METHOD | CLAMP" |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION" |
CSCF | TERMINAL TYPE | WIRE LEAD" |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 500.0 MILLIAMPERES INDUCTIVE LOAD FIRST VOLTAGE AND 200.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE AND 500.0 MILLIAMPERES INDUCTIVE LOAD SECOND VOLTAGE AND 200.0 MILLIAMPERES LAMP LOAD SECOND VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE" |
CTYX | CONTACT STIMULUS RATING | 262.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 232.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 248.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 30.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE" |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID" |
STYL | III STYLE DESIGNATOR | DISC" |
TEST | TEST DATA DOCUMENT | 81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-S-24236/13 GOVERNMENT SPECIFICATION" |
ABHP | III OVERALL LENGTH | 0.322 INCHES MINIMUM AND 0.366 INCHES MAXIMUM" |
ABKW | OVERALL HEIGHT | 0.065 INCHES MINIMUM AND 0.095 INCHES MAXIMUM" |
ABPM | BODY DIAMETER | 0.248 INCHES MINIMUM AND 0.278 INCHES MAXIMUM" |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR" |
AXGY | MOUNTING METHOD | CLAMP" |
CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION" |
CSCF | TERMINAL TYPE | WIRE LEAD" |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 500.0 MILLIAMPERES INDUCTIVE LOAD FIRST VOLTAGE AND 200.0 MILLIAMPERES LAMP LOAD FIRST VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 500.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE AND 500.0 MILLIAMPERES INDUCTIVE LOAD SECOND VOLTAGE AND 200.0 MILLIAMPERES LAMP LOAD SECOND VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE" |
CTYX | CONTACT STIMULUS RATING | 262.00 ACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 232.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND 248.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT AND 30.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE" |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID" |
STYL | III STYLE DESIGNATOR | DISC" |
TEST | TEST DATA DOCUMENT | 81349-MIL-S-24236 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-S-24236/13 GOVERNMENT SPECIFICATION" |