MRC | Criteria | Characteristic |
---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTTIGHT" |
ABHP | III OVERALL LENGTH | 2.156 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 4.406 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.260 INCHES NOMINAL" |
AEVT | CAPILLARY TUBE LENGTH | 72.0 INCHES NOMINAL" |
AEVU | BULB LENGTH | 4.000 INCHES NOMINAL" |
AEVV | BULB DIAMETER | 0.375 INCHES NOMINAL" |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.562 INCHES NOMINAL" |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.938 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB" |
AWTN | OPERATING TEMP RATING | 140.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | SURFACE AND SLOT" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CSCF | TERMINAL TYPE | SCREW" |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 7.2 AMPERES RESISTIVE LOAD FIRST VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | -30.00/+50.00 ACTUATION POINT DEGREES FAHRENHEIT AND -28.00/+48.00 DEACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB WITH SCALE AND EXTERNAL ACTUATION POINT KNOB WITH SCALE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 277.0 AC AT SEA LEVEL FIRST VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS" |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DUSTTIGHT" |
ABHP | III OVERALL LENGTH | 2.156 INCHES NOMINAL" |
ABKW | OVERALL HEIGHT | 4.406 INCHES NOMINAL" |
ABMK | OVERALL WIDTH | 2.260 INCHES NOMINAL" |
AEVT | CAPILLARY TUBE LENGTH | 72.0 INCHES NOMINAL" |
AEVU | BULB LENGTH | 4.000 INCHES NOMINAL" |
AEVV | BULB DIAMETER | 0.375 INCHES NOMINAL" |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.562 INCHES NOMINAL" |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 2.938 INCHES NOMINAL" |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE-BULB" |
AWTN | OPERATING TEMP RATING | 140.0 DEG FAHRENHEIT MAXIMUM" |
AXGY | MOUNTING METHOD | SURFACE AND SLOT" |
CQGB | CONTACT ACTION STIMULUS | INCREASE" |
CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR" |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY" |
CSCF | TERMINAL TYPE | SCREW" |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE" |
CTHF | CONTACT LOAD CURRENT RATING | 7.2 AMPERES RESISTIVE LOAD FIRST VOLTAGE" |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE" |
CTYM | CONTACT ADJUSTMENT RANGE | -30.00/+50.00 ACTUATION POINT DEGREES FAHRENHEIT AND -28.00/+48.00 DEACTUATION POINT DEGREES FAHRENHEIT" |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL DEACTUATION POINT KNOB WITH SCALE AND EXTERNAL ACTUATION POINT KNOB WITH SCALE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL SECOND VOLTAGE" |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 277.0 AC AT SEA LEVEL FIRST VOLTAGE" |
MEDA | MEDIA FOR WHICH DESIGNED | GAS" |