MRC | Criteria | Characteristic |
---|
AAQL | | " |
ADAQ | BODY LENGTH | 2.490 INCHES NOMINAL" |
ADAT | BODY WIDTH | 4.500 INCHES MAXIMUM" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.928 INCHES NOMINAL" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL" |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.060 INCHES NOMINAL" |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL" |
AJEC | BOSS HEIGHT | 0.150 INCHES NOMINAL" |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.656 INCHES MAXIMUM" |
AKPX | POLE QUANTITY | 6" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 12 THREADED HOLE" |
CMLP | THREAD QUANTITY PER INCH | 32" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS AND 50.0 AMPERES DC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC ALL LOCATIONS AND 28.0 DC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1500.0 AC ALL LOCATIONS AND 2000.0 DC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 6 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE" |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, FOUR, FIVE, AND SIX LINKED" |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.150 MINIMUM AT 200 PCT ALL LOCATIONS AND 19.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND MOISTURE RESISTANT" |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS" |
TEST | TEST DATA DOCUMENT | 13499-260-1015 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA" |
THSD | THREAD SERIES DESIGNATOR | UNC" |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD" |
AAQL | | " |
ADAQ | BODY LENGTH | 2.490 INCHES NOMINAL" |
ADAT | BODY WIDTH | 4.500 INCHES MAXIMUM" |
ADTV | CASE MATERIAL | PLASTIC" |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.928 INCHES NOMINAL" |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL" |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.060 INCHES NOMINAL" |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL" |
AJEC | BOSS HEIGHT | 0.150 INCHES NOMINAL" |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.656 INCHES MAXIMUM" |
AKPX | POLE QUANTITY | 6" |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 12 THREADED HOLE" |
CMLP | THREAD QUANTITY PER INCH | 32" |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS AND 50.0 AMPERES DC ALL LOCATIONS" |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC ALL LOCATIONS AND 28.0 DC ALL LOCATIONS" |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1500.0 AC ALL LOCATIONS AND 2000.0 DC ALL LOCATIONS" |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS" |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS" |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS" |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS" |
CPRQ | RESET METHOD | MANUAL" |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE" |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 6 TOGGLE" |
CPRW | ACTUATOR FUNCTION | TRIP-RESET" |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE" |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, FOUR, FIVE, AND SIX LINKED" |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS" |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES" |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.150 MINIMUM AT 200 PCT ALL LOCATIONS AND 19.000 MAXIMUM AT 200 PCT ALL LOCATIONS" |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND MOISTURE RESISTANT" |
FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS" |
TEST | TEST DATA DOCUMENT | 13499-260-1015 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA" |
THSD | THREAD SERIES DESIGNATOR | UNC" |
TTQY | TERMINAL TYPE AND QUANTITY | 12 THREADED STUD" |