NSN 5925-00-927-5434 (5925009275434) Circuit Breaker Parts Catalog

The part belongs to NSN 5925-00-927-5434 is an Circuit Breaker produced by Eca Etablissement Central Des, Eaton Corp Heinemann Products Co, Cecom Lr Center. This specific NSN is a numeric identifier assigned by the Defense Logistics Agency (DLA) to categorize all products distributed by the NATO federal supply chain. At ASAP AOG, a company owned and operated by ASAP Semiconductor, we possess parts that belong to the NSN 5925-00-927-5434 and these are readily available in our current inventory. Our on-hand inventory contains parts belonging to this particular NSN that you can easily access. So, if you need an Circuit Breaker made by Eca Etablissement Central Des, Eaton Corp Heinemann Products Co, Cecom Lr Center that carries the NSN 5925-00-927-5434, you can rely on us to provide you with the necessary parts from our available inventory.


At ASAP AOG, we are dedicated to providing competitive quotes for premium NATO parts. We work hard to ensure all the national stock number 5925009275434 parts are fully certified and up to standard. Our supply chain is extensive and one of the fastest in the industry. Have a question or need a quote today? Simply fill out the RFQ below.


Alternative NSN: 5925-00-927-5434
Item Name: Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NCB Code: USA (00)
Manufacturers: Cecom Lr Center, Eaton Corp Heinemann Products Co, Eca Etablissement Central Des

Manufacturer’s List for NSN 5925-00-927-5434

cecom lr center eaton corp heinemann products co eca etablissement central des

Part Number's List for NSN 5925-00-927-5434

Part No.
Manufacturer
Item Name
Availability
RFQ
Circuit Breaker
YES
RFQ

Technical Characteristics of NSN 5925009275434

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE"
ADAQBODY LENGTH3.709 INCHES MINIMUM AND"
ADATBODY WIDTH3.042 INCHES MINIMUM AND 3.062 INCHES MAXIMUM"
ADTVCASE MATERIALPLASTIC"
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.053 INCHES MINIMUM AND 3.073 INCHES MAXIMUM"
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.021 INCHES MINIMUM AND 1.041 INCHES MAXIMUM"
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM"
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.021 INCHES MINIMUM AND 1.041 INCHES MAXIMUM"
AFJNFRAGILITY FACTORMODERATELY RUGGED"
AJECBOSS HEIGHT0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM"
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE3.239 INCHES NOMINAL"
AKPXPOLE QUANTITY3"
APNQARC QUENCHING METHODMAGNETIC BLOWOUT"
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE"
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE"
BBRJSPECIAL HANDLING FEATUREMAGNETIC"
CMLPTHREAD QUANTITY PER INCH32"
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE60.0 AMPERES AC FIRST LOCATION60.0 AMPERES AC SECOND LOCATION30.0 AMPERES AC THIRD LOCATION"
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC ALL LOCATIONS"
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1500.0 AC ALL LOCATIONS"
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS"
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS"
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS ALL LOCATIONS"
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS"
CPRQRESET METHODMANUAL"
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE"
CPRTMANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE"
CPRWACTUATOR FUNCTIONTRIP-RESET"
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE"
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED"
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS"
CQJXNOMINAL THREAD SIZE0.138 INCHES"
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT"
FREQFREQUENCY IN HERTZ400.0 ALL LOCATIONS"
THSDTHREAD SERIES DESIGNATORUNC"
TTQYTERMINAL TYPE AND QUANTITY6 THREADED STUD"
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE"
ADAQBODY LENGTH3.709 INCHES MINIMUM AND"
ADATBODY WIDTH3.042 INCHES MINIMUM AND 3.062 INCHES MAXIMUM"
ADTVCASE MATERIALPLASTIC"
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH3.053 INCHES MINIMUM AND 3.073 INCHES MAXIMUM"
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH1.021 INCHES MINIMUM AND 1.041 INCHES MAXIMUM"
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.740 INCHES MINIMUM AND 2.760 INCHES MAXIMUM"
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.021 INCHES MINIMUM AND 1.041 INCHES MAXIMUM"
AFJNFRAGILITY FACTORMODERATELY RUGGED"
AJECBOSS HEIGHT0.146 INCHES MINIMUM AND 0.166 INCHES MAXIMUM"
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE3.239 INCHES NOMINAL"
AKPXPOLE QUANTITY3"
APNQARC QUENCHING METHODMAGNETIC BLOWOUT"
AXHRMOUNTING FACILITY TYPE AND QUANTITY6 THREADED HOLE"
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE"
BBRJSPECIAL HANDLING FEATUREMAGNETIC"
CMLPTHREAD QUANTITY PER INCH32"
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE60.0 AMPERES AC FIRST LOCATION60.0 AMPERES AC SECOND LOCATION30.0 AMPERES AC THIRD LOCATION"
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS250.0 AC ALL LOCATIONS"
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS1500.0 AC ALL LOCATIONS"
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS"
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS"
CPRLTRIP RELEASE CHARACTERISTICINSTANTANEOUS ALL LOCATIONS"
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS"
CPRQRESET METHODMANUAL"
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE"
CPRTMANUAL ACTUATOR TYPE AND QUANTITY3 TOGGLE"
CPRWACTUATOR FUNCTIONTRIP-RESET"
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE"
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED"
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS"
CQJXNOMINAL THREAD SIZE0.138 INCHES"
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT"
FREQFREQUENCY IN HERTZ400.0 ALL LOCATIONS"
THSDTHREAD SERIES DESIGNATORUNC"
TTQYTERMINAL TYPE AND QUANTITY6 THREADED STUD"