NSN 5925-00-802-6074 (5925008026074) Circuit Breaker Parts Catalog

The part belongs to NSN 5925-00-802-6074 is an Circuit Breaker produced by Televiso Corp, Eaton Corp Heinemann Products Co. This specific NSN is a numeric identifier assigned by the Defense Logistics Agency (DLA) to categorize all products distributed by the NATO federal supply chain. At ASAP AOG, a company owned and operated by ASAP Semiconductor, we possess parts that belong to the NSN 5925-00-802-6074 and these are readily available in our current inventory. Our on-hand inventory contains parts belonging to this particular NSN that you can easily access. So, if you need an Circuit Breaker made by Televiso Corp, Eaton Corp Heinemann Products Co that carries the NSN 5925-00-802-6074, you can rely on us to provide you with the necessary parts from our available inventory.


At ASAP AOG, we are dedicated to providing competitive quotes for premium NATO parts. We work hard to ensure all the national stock number 5925008026074 parts are fully certified and up to standard. Our supply chain is extensive and one of the fastest in the industry. Have a question or need a quote today? Simply fill out the RFQ below.


Alternative NSN: 5925-00-802-6074
Item Name: Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NCB Code: USA (00)
Manufacturers: Eaton Corp Heinemann Products Co, Televiso Corp

Manufacturer’s List for NSN 5925-00-802-6074

eaton corp heinemann products co televiso corp

Part Number's List for NSN 5925-00-802-6074

Part No.
Manufacturer
Item Name
Availability
RFQ
Circuit Breaker
YES
RFQ

Technical Characteristics of NSN 5925008026074

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE"
ADAQBODY LENGTH2.500 INCHES NOMINAL"
ADATBODY WIDTH1.500 INCHES NOMINAL"
ADTVCASE MATERIALPLASTIC"
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.938 INCHES NOMINAL"
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.750 INCHES NOMINAL"
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.060 INCHES NOMINAL"
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.750 INCHES NOMINAL"
AFJNFRAGILITY FACTORMODERATELY RUGGED"
AJECBOSS HEIGHT0.150 INCHES NOMINAL"
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.611 INCHES NOMINAL"
AKPXPOLE QUANTITY2"
APNQARC QUENCHING METHODMAGNETIC BLOWOUT"
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE"
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE"
BBRJSPECIAL HANDLING FEATUREMAGNETIC"
CMLPTHREAD QUANTITY PER INCH32"
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES AC ALL LOCATIONS AND 200.0 MILLIAMPERES AC ALL LOCATIONS"
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS120.0 AC ALL LOCATIONS"
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS2000.0 AC ALL LOCATIONS"
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS"
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS AND MAGNETIC-HYDRAULIC ALL LOCATIONS"
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS"
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS"
CPRPULTIMATE TRIP TIME PER POLE IN SECONDS15.000 NOMINAL ALL LOCATIONS"
CPRQRESET METHODMANUAL"
CPRRMAIN CONTACT TRIPPING MECHANISM TYPENONTRIP FREE"
CPRTMANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE"
CPRWACTUATOR FUNCTIONTRIP-RESET"
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE"
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED"
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS"
CQJXNOMINAL THREAD SIZE0.138 INCHES"
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT7.000 NOMINAL AT 150 PCT ALL LOCATIONS AND 1.000 NOMINAL AT 300 PCT ALL LOCATIONS"
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANT AND FUNGUS RESISTANT AND EXPLOSION RESISTANT"
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS"
THSDTHREAD SERIES DESIGNATORUNC"
TTQYTERMINAL TYPE AND QUANTITY4 THREADED STUD"
AAQLBODY STYLEMULTIPOLE-MULTIPLE ACTUATOR TYPE"
ADAQBODY LENGTH2.500 INCHES NOMINAL"
ADATBODY WIDTH1.500 INCHES NOMINAL"
ADTVCASE MATERIALPLASTIC"
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.938 INCHES NOMINAL"
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH0.750 INCHES NOMINAL"
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.060 INCHES NOMINAL"
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH0.750 INCHES NOMINAL"
AFJNFRAGILITY FACTORMODERATELY RUGGED"
AJECBOSS HEIGHT0.150 INCHES NOMINAL"
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCE2.611 INCHES NOMINAL"
AKPXPOLE QUANTITY2"
APNQARC QUENCHING METHODMAGNETIC BLOWOUT"
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE"
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE"
BBRJSPECIAL HANDLING FEATUREMAGNETIC"
CMLPTHREAD QUANTITY PER INCH32"
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE5.0 AMPERES AC ALL LOCATIONS AND 200.0 MILLIAMPERES AC ALL LOCATIONS"
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS120.0 AC ALL LOCATIONS"
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS2000.0 AC ALL LOCATIONS"
CPRHCIRCUIT PROTECTION TYPEOVERCURRENT ALL LOCATIONS"
CPRJTRIP RELEASE METHODMAGNETIC-HYDRAULIC ALL LOCATIONS AND MAGNETIC-HYDRAULIC ALL LOCATIONS"
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS"
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT125.0 ALL LOCATIONS"
CPRPULTIMATE TRIP TIME PER POLE IN SECONDS15.000 NOMINAL ALL LOCATIONS"
CPRQRESET METHODMANUAL"
CPRRMAIN CONTACT TRIPPING MECHANISM TYPENONTRIP FREE"
CPRTMANUAL ACTUATOR TYPE AND QUANTITY2 TOGGLE"
CPRWACTUATOR FUNCTIONTRIP-RESET"
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE"
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE AND TWO LINKED"
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSERIES TRIP ALL LOCATIONS"
CQJXNOMINAL THREAD SIZE0.138 INCHES"
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT7.000 NOMINAL AT 150 PCT ALL LOCATIONS AND 1.000 NOMINAL AT 300 PCT ALL LOCATIONS"
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANT AND FUNGUS RESISTANT AND EXPLOSION RESISTANT"
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS"
THSDTHREAD SERIES DESIGNATORUNC"
TTQYTERMINAL TYPE AND QUANTITY4 THREADED STUD"