Search By:
Thanks for Visiting Us At ASAP AOG!

Thanks for Visiting Us At ASAP AOG! Before You Go, Why Not Take a Look at Our Aircraft Parts Catalog? You Can Get One of the Most Competitive Quotes On the Market In 15 Minutes Or Less.

Request for Quote

We use cookies to ensure that we give you an amazing experience on our website. If you continue to use this site we will assume that you are happy with it.

NSN 5925-00-109-9161 (5925001099161) Circuit Breaker Parts Catalog

The part belongs to NSN 5925-00-109-9161 is an Circuit Breaker produced by Sacramento Electronic Supply Co Inc, Lake Shore Inc. This specific NSN is a numeric identifier assigned by the Defense Logistics Agency (DLA) to categorize all products distributed by the NATO federal supply chain. At ASAP AOG, a company owned and operated by ASAP Semiconductor, we possess parts that belong to the NSN 5925-00-109-9161 and these are readily available in our current inventory. Our on-hand inventory contains parts belonging to this particular NSN that you can easily access. So, if you need an Circuit Breaker made by Sacramento Electronic Supply Co Inc, Lake Shore Inc that carries the NSN 5925-00-109-9161, you can rely on us to provide you with the necessary parts from our available inventory.


At ASAP AOG, we are dedicated to providing competitive quotes for premium NATO parts. We work hard to ensure all the national stock number 5925001099161 parts are fully certified and up to standard. Our supply chain is extensive and one of the fastest in the industry. Have a question or need a quote today? Simply fill out the RFQ below.


Alternative NSN: 5925-00-109-9161
Item Name: Circuit Breaker
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5925 Circuit Breakers
NCB Code: USA (00)
Manufacturers: Lake Shore Inc, Sacramento Electronic Supply Co Inc

Manufacturer’s List for NSN 5925-00-109-9161

lake shore inc sacramento electronic supply co inc

Part Number's List for NSN 5925-00-109-9161

Part No.
Manufacturer
Item Name
Availability
RFQ
Circuit Breaker
YES
RFQ

Technical Characteristics of NSN 5925001099161

MRCCriteriaCharacteristic
AAQLBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE"
ADAQBODY LENGTH17.000 INCHES NOMINAL"
ADATBODY WIDTH8.000 INCHES MINIMUM AND 8.500 INCHES MAXIMUM"
AEBVUNTHREADED MOUNTING HOLE DIAMETER1.031 INCHES NOMINAL"
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH14.750 INCHES NOMINAL"
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.750 INCHES NOMINAL"
AKPXPOLE QUANTITY3"
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE"
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE800.0 AMPERES AC ALL LOCATIONS"
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS600.0 AC ALL LOCATIONS"
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS10000.0 AC ALL LOCATIONS"
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS"
CPRQRESET METHODMANUAL"
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE"
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT280.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 950.000 MAXIMUM AT 200 PCT ALL LOCATIONS"
CRCFTRIP RELEASE AMBIENT TEMP RATING40.0 DEG CELSIUS NOMINAL ALL LOCATIONS"
FEATSPECIAL FEATURESMAIN CONTACTS PROTECTED BY ARCING CONTACTS,ARC BARRIERS AND MAGNETIC BLOWOUTS; MAIN CONTACTS SELF-ALIGNING,SELF-CLEANING AND REMOVABLE"
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS"
SPCLSPECIAL TEST FEATURESDIELECTRIC STRENGTH MUST PASS EQUIVALENT OF 1960V BETWEEN LIVE PARTS AND GROUND AND BETWEEN POLES FOR 1 SECOND IN BOTH OPEN AND CLOSED POSITIONS; MUST INTERRUPT 350 PERCENT AT 60 HZ OF ITS RATED CURRENT AT 208V FOR 30 OPERATIONS AT 10 SECON"
AAQLBODY STYLEMULTIPOLE-SINGLE ACTUATOR TYPE"
ADAQBODY LENGTH17.000 INCHES NOMINAL"
ADATBODY WIDTH8.000 INCHES MINIMUM AND 8.500 INCHES MAXIMUM"
AEBVUNTHREADED MOUNTING HOLE DIAMETER1.031 INCHES NOMINAL"
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH14.750 INCHES NOMINAL"
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.750 INCHES NOMINAL"
AKPXPOLE QUANTITY3"
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE"
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE800.0 AMPERES AC ALL LOCATIONS"
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS600.0 AC ALL LOCATIONS"
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS10000.0 AC ALL LOCATIONS"
CPRLTRIP RELEASE CHARACTERISTICTIME DELAY ALL LOCATIONS"
CPRQRESET METHODMANUAL"
CPRTMANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE"
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT280.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 950.000 MAXIMUM AT 200 PCT ALL LOCATIONS"
CRCFTRIP RELEASE AMBIENT TEMP RATING40.0 DEG CELSIUS NOMINAL ALL LOCATIONS"
FEATSPECIAL FEATURESMAIN CONTACTS PROTECTED BY ARCING CONTACTS,ARC BARRIERS AND MAGNETIC BLOWOUTS; MAIN CONTACTS SELF-ALIGNING,SELF-CLEANING AND REMOVABLE"
FREQFREQUENCY IN HERTZ60.0 ALL LOCATIONS"
SPCLSPECIAL TEST FEATURESDIELECTRIC STRENGTH MUST PASS EQUIVALENT OF 1960V BETWEEN LIVE PARTS AND GROUND AND BETWEEN POLES FOR 1 SECOND IN BOTH OPEN AND CLOSED POSITIONS; MUST INTERRUPT 350 PERCENT AT 60 HZ OF ITS RATED CURRENT AT 208V FOR 30 OPERATIONS AT 10 SECON"