MRC | Criteria | Characteristic |
---|
EXTRACTOR POST | AAFZ | BODY MATERIALPLASTIC |
EXTRACTOR POST | AAQL | BODY STYLEPANEL MOUNTED TYPE |
EXTRACTOR POST | ABHP | OVERALL LENGTH2 150 INCHES MINIMUM AND 2 230 INCHES MAXIMUM |
EXTRACTOR POST | ABKW | OVERALL HEIGHT2 260 INCHES MINIMUM AND 2 300 INCHES MAXIMUM |
EXTRACTOR POST | ABMK | OVERALL WIDTH2 040 INCHES MINIMUM AND 2 080 INCHES MAXIMUM |
EXTRACTOR POST | ABTB | MOUNTING HOLE DIAMETER0 147 INCHES MINIMUM AND 0 157 INCHES MAXIMUM |
EXTRACTOR POST | ABTJ | MOUNTING HOLE QUANTITY1 AND 3 |
EXTRACTOR POST | ADEE | PANEL THICKNESS0 187 INCHES MAXIMUM |
EXTRACTOR POST | ADZC | ENVIRONMENTAL PROTECTIONWATERTIGHT |
EXTRACTOR POST | AEVB | MOUNTING HOLE STYLEPANEL MOUNTING W2 OR 3 HOLES |
EXTRACTOR POST | AFRG | CONTACT MATERIALANY ACCEPTABLE |
EXTRACTOR POST | AFRH | CONTACT SURFACE TREATMENTSILVER PLATED QQ-S-365 |
EXTRACTOR POST | AFXH | INTERRUPTION INDICATOR METHODNEON LAMP |
EXTRACTOR POST | AGUE | FUSE ACCOMMODATION QUANTITY2 |
EXTRACTOR POST | AGUJ | ACCOMMODATED FUSE LENGTH1 500 INCHES NOMINAL |
EXTRACTOR POST | AGUK | ACCOMMODATED FERRULE DIAMETER0 406 INCHES NOMINAL |
EXTRACTOR POST | AGUN | RESISTOR RATING330 0 KILOHMS AND 330 0 KILOHMS |
EXTRACTOR POST | AGUP | INDICATING LAMP VOLTAGE RANGE IN VOLTS90 0500 0 AND 90 0500 0 |
EXTRACTOR POST | AGUT | LENGTH FROM FRONT PROTRUSION TO MOUNTING SURFACE1 170 INCHES MINIMUM AND 1 210 INCHES MAXIMUM |
EXTRACTOR POST | AGUV | CAP DIAMETER0 600 INCHES MINIMUM AND 0 640 INCHES MAXIMUM |
EXTRACTOR POST | AGUW | MOUNTING HOLE HEIGHT1 820 INCHES MINIMUM AND 1 860 INCHES MAXIMUM |
EXTRACTOR POST | AGUX | MOUNTING HOLE WIDTH1 540 INCHES MINIMUM AND 1 580 INCHES MAXIMUM |
EXTRACTOR POST | AGVA | CENTER TO CENTER DISTANCE BETWEEN OUTSIDE MOUNTING HOLES ALONG LENGTH1 950 INCHES MINIMUM AND 1 960 INCHES MAXIMUM |
EXTRACTOR POST | AGVB | CENTER TO CENTER DISTANCE BETWEEN OUTSIDE MOUNTING HOLES ALONG WIDTH0 990 INCHES MINIMUM AND 1 000 INCHES MAXIMUM |
EXTRACTOR POST | AJYN | SCREW THREAD DIAMETER0 164 INCHES NOMINAL |
EXTRACTOR POST | AJYQ | SCREW THREAD QUANTITY PER INCH32 0 |
EXTRACTOR POST | CQJL | CURRENT CARRYING RATING IN AMPS30 0 |
EXTRACTOR POST | CSNM | FUSE TERMINAL TYPE ACCOMMODATEDFERRULE |
EXTRACTOR POST | ELEC | VOLTAGE IN VOLTS500 0 |
EXTRACTOR POST | PMLC | PRECIOUS MATERIAL AND LOCATIONCONTACT SURFACES SILVER |
EXTRACTOR POST | PRMT | PRECIOUS MATERIALSILVER |
EXTRACTOR POST | TEST | TEST DATA DOCUMENT81349-MIL-F-19207 SPECIFICATION INCLUDES ENGINEERING TYPE BULLETINS BROCHURESETC THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT EXCLUDES COMMERCIAL CATALOGS INDUSTRY DIRECTORIES AND SIMILAR TRADE PUBLICATIONS REFLECTI |
EXTRACTOR POST | TTQY | TERMINAL TYPE AND QUANTITY4 THREADED STUD |
EXTRACTOR POST | ZZZK | SPECIFICATIONSTANDARD DATA81349-MIL-F-1920723 GOVERNMENT SPECIFICATION |