MRC | Criteria | Characteristic |
---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -100.0/+100.0" |
AAPP | ELECTRICAL RESISTANCE | 24.900 OHMS" |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000/+1.000" |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0" |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0" |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+150.0" |
AAQZ | INCLOSURE METHOD | ENCAPSULATED" |
AARB | TERMINAL TYPE | WIRE LEAD" |
AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | C" |
AARG | RELIABILITY INDICATOR | ESTABLISHED" |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010" |
ABJT | TERMINAL LENGTH | 0.984 INCHES MINIMUM AND 1.516 INCHES MAXIMUM" |
ABPM | BODY DIAMETER | 0.058 INCHES MINIMUM AND 0.074 INCHES MAXIMUM" |
ADAQ | BODY LENGTH | 0.130 INCHES MINIMUM AND 0.170 INCHES MAXIMUM" |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.250 FREE AIR" |
AGAV | END ITEM IDENTIFICATION | 5865014392738" |
PKWT | UNPACKAGED UNIT WEIGHT | 0.3 GRAMS" |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END" |
TEST | TEST DATA DOCUMENT | 81349-MIL-PRF-39017 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLEC" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-39017/5 GOVERNMENT SPECIFICATION" |
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -100.0/+100.0" |
AAPP | ELECTRICAL RESISTANCE | 24.900 OHMS" |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000/+1.000" |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 70.0" |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 150.0" |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+150.0" |
AAQZ | INCLOSURE METHOD | ENCAPSULATED" |
AARB | TERMINAL TYPE | WIRE LEAD" |
AARF | MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR | C" |
AARG | RELIABILITY INDICATOR | ESTABLISHED" |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010" |
ABJT | TERMINAL LENGTH | 0.984 INCHES MINIMUM AND 1.516 INCHES MAXIMUM" |
ABPM | BODY DIAMETER | 0.058 INCHES MINIMUM AND 0.074 INCHES MAXIMUM" |
ADAQ | BODY LENGTH | 0.130 INCHES MINIMUM AND 0.170 INCHES MAXIMUM" |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.250 FREE AIR" |
AGAV | END ITEM IDENTIFICATION | 5865014392738" |
PKWT | UNPACKAGED UNIT WEIGHT | 0.3 GRAMS" |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END" |
TEST | TEST DATA DOCUMENT | 81349-MIL-PRF-39017 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLEC" |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-39017/5 GOVERNMENT SPECIFICATION" |