MRC | Criteria | Characteristic |
---|
AAPN | SECTION QUANTITY | 1" |
AAQL | BODY STYLE | RECTANGULAR" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABJT | TERMINAL LENGTH | 0.188 INCHES NOMINAL" |
ABWV | SHAFT DIAMETER | 0.090 INCHES NOMINAL" |
ABXF | SHAFT LENGTH | 0.060 INCHES NOMINAL" |
ADAQ | BODY LENGTH | 0.375 INCHES NOMINAL" |
ADAT | BODY WIDTH | 0.190 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 0.437 INCHES NOMINAL" |
AEDX | SHAFT STYLE | ROUND, SLOTTED" |
AEFD | ACTUATOR TYPE | SINGLE SHAFT" |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES" |
AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES" |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AGAV | END ITEM IDENTIFICATION | 6625-01-146-1554 TEST SET,ELECTRICAL METER" |
APXH | TERMINAL LOCATION | REAR END" |
AXGY | MOUNTING METHOD | TERMINAL" |
CBME | III CUBIC MEASURE | 0.031 CUBIC INCHES" |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 20.0 KILOHMS SINGLE SECTION" |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL" |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION" |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION" |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 SINGLE SECTION" |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION" |
CSDL | UNABLE TO DECODE | UNABLE TO DECODE" |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN" |
ZZZK | SPECIFICATION/STANDARD DATA | 55597-RV0001942A MANUFACTURERS SPECIFICATION CONTROL" |
AAPN | SECTION QUANTITY | 1" |
AAQL | BODY STYLE | RECTANGULAR" |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED" |
ABJT | TERMINAL LENGTH | 0.188 INCHES NOMINAL" |
ABWV | SHAFT DIAMETER | 0.090 INCHES NOMINAL" |
ABXF | SHAFT LENGTH | 0.060 INCHES NOMINAL" |
ADAQ | BODY LENGTH | 0.375 INCHES NOMINAL" |
ADAT | BODY WIDTH | 0.190 INCHES NOMINAL" |
ADAU | BODY HEIGHT | 0.437 INCHES NOMINAL" |
AEDX | SHAFT STYLE | ROUND, SLOTTED" |
AEFD | ACTUATOR TYPE | SINGLE SHAFT" |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES" |
AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES" |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL" |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED" |
AGAV | END ITEM IDENTIFICATION | 6625-01-146-1554 TEST SET,ELECTRICAL METER" |
APXH | TERMINAL LOCATION | REAR END" |
AXGY | MOUNTING METHOD | TERMINAL" |
CBME | III CUBIC MEASURE | 0.031 CUBIC INCHES" |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 20.0 KILOHMS SINGLE SECTION" |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 INCHES NOMINAL" |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 125.0 SINGLE SECTION" |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 FREE AIR SINGLE SECTION" |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10.0/+10.0 SINGLE SECTION" |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION" |
CSDL | UNABLE TO DECODE | UNABLE TO DECODE" |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN" |
ZZZK | SPECIFICATION/STANDARD DATA | 55597-RV0001942A MANUFACTURERS SPECIFICATION CONTROL" |